您现在的位置:  
 首 页 > ADS > ADS百科问答 > ADS layout生成器件后引入到电路仿真报错,求助

ADS layout生成器件后引入到电路仿真报错,求助

文章来源: 互联网    录入: mweda.com    点击数:

各位大侠,我经常遇到在layout进行场仿真后(仿真和结果顺利进行,无报错),但是在拉入到电路仿真s参数时候,报错如下,求教!


ADS.GIF


微波EDA (www.mweda.com) 网友回复:

  • 网友回复

    重贴一下报错内容:
    Simulation / Synthesis Messages

    Warning detected by hpeesofsim in topology check during circuit set up.
        Number of nodes with only one device attached (topology corrected): 5
        Number of nodes with no DC path to ground (topology corrected): 19
    Error detected by hpeesofsim during TRAN analysis 'SP1'.
        `test_1': S-parameters are not available at 0 Hz.
    Error detected by hpeesofsim during TRAN analysis 'SP1'.
        Fatal error occurred while evaluating model `MomCmpt', instance `test_1'.

    Status / Summary


    hpeesofsim (*) 331.200 May  6 2008 (built: 05/06/08 00:26:15)
    Copyright Agilent Technologies, 1989-2008.

    ******************************************
    ***** Abnormal Simulator Termination *****
    ******************************************
    The simulator has unexpectedly terminated.
  • 网友回复

    可能是你在layout下的频率设置和schematic下的不同。
  • 网友回复

    频率设成一直也不管用啊,那位高手帮忙解答胰一下怎么化解啊?
    Simulation / Synthesis Messages
    Warning detected by hpeesofsim in topology check during circuit set up.
        Number of nodes with only one device attached (topology corrected): 10
    Error detected by hpeesofsim during SP analysis 'SP1'.
        `X090224_output_1': Syntax error in the Layout Component ModelDatabase citi-file.
    Error detected by hpeesofsim during SP analysis 'SP1'.
        Fatal error occurred while evaluating model `MomCmpt', instance `X090224_output_1'.
    Status / Summary

申明:网友回复良莠不齐,仅供参考。如需专业解答,推荐学习李明洋老师的ADS培训视频,或咨询本站专家

  • 上一个教程:
  • 下一个教程:
  • 推荐课程

    射频工程师学习培训教程