淘宝官方店     推荐课程     在线工具     联系方式     关于我们  
 
 

微波射频仿真设计   Ansoft Designer 中文培训教程   |   HFSS视频培训教程套装

 

Agilent ADS 视频培训教程   |   CST微波工作室视频教程   |   AWR Microwave Office

          首页 >> Ansoft Designer >> Ansoft Designer在线帮助文档


Ansoft Designer / Ansys Designer 在线帮助文档:


Nexxim Simulator >
Nexxim Linear Network Analysis >
   LNA Options       


LNA Options

In a netlist, options are specified with the .OPTIONS statement. In Schematic Editor designs, options are specified with the Add Solution Options dialog box.

ZERO_PORT_VALUES

Port impedance resistors specify the port impedances with their PORTNUM parameters (see Resistor, Port Impedance for details). LNA needs to treat these impedances as external to the circuit. The model option ZERO_PORT_VALUES=1 is therefore required for LNA.

The ZERO_PORT_VALUES option is automatically enabled with any design entered through the Schematic Editor in Designer. It does not appear on the list of Analysis Options in the Schematic Editor. For designs entered with the Netlist Editor, the ZERO_PORT_VALUES option must be entered explicitly with a .OPTIONS statement.

Nexxim DC Analysis Options in LNA

All DC Analysis options apply to the operating point analysis that is performed at the start of LNA. See DC Analysis Options in Nexxim Help.

Nexxim S-Parameter Element Options in LNA

For designs that incorporate s-parameter elements, setting the s-parameter option time_domain_s_model=1 causes Nexxim to create a state-space system for the analysis. Normally, a state-space system would not be generated for frequency-domain analyses such as LNA. See S-Element Options.

 


Nexxim Linear Network Analysis Options

Option

Default Value

Description

flag

LNA

LNA=simple AC analysis

NOISE_DC=noise analysis

LNAN=AC and noise

LNAG=AC and group delay

LNANG=AC, noise, and group delay

group_delay_pert

None

Perturbation (percentage of the test frequency) to be applied in group delay calculation

input_referred_noise

None

Node voltage, branch, or current to be used as the source for an input-referred noise calculation

result_as_initial_guess

1

Use LNA solution as initial guess in sweep

noise_output

None

Output nodes where noise should be computed in noise analysis. No noise factor or conversion gain is computed for these outputs

skip_dc

no

yes=Field solvers need not solve for DC. Use this option only for circuits with linear devices and no non-zero-valued sources except AC sources.

no=Solve for DC.

small_signal_beta

1e-12

Minimum conductance from node to ground in small-signal analysis

ZERO_PORT_VALUES

TRUE

Enable use of port impedance resistors


 




HFSS视频教学培训教程 ADS2011视频培训教程 CST微波工作室教程 Ansoft Designer 教程

                HFSS视频教程                                      ADS视频教程                               CST视频教程                           Ansoft Designer 中文教程


 

      Copyright © 2006 - 2013   微波EDA网, All Rights Reserved    业务联系:mweda@163.com