微波射频仿真设计 |
|
首页 >> Ansoft Designer >> Ansoft Designer在线帮助文档 |
Nexxim Simulator > Calculated Model OutputsCertain device models have been set up to provide calculated quantities as outputs. To enable the output quantities, the netlist uses a variation of the .PRINT statement: .PRINT analysis O(instance_name) The analysis is one of the Nexxim analysis types listed above. The instance_name is the name of a device instance defined elsewhere in the netlist. The outputs are calculated values particular to the device model referenced by the instance statement. Here is a netlist fragment: .MODEL bsim_model NMOS LEVEL=53 // Device model The output quantities are listed in the documentation for the individual devices. Since the >PRINT statement references the instance name, the output quantities are documented under the instance statement for the device types. See the documentation for the MOSFET instance, Level 49 or 53 for an example. To display the calculated quantities in a Report window: 1. Select Create Report from the Results icon in the Project window. Click OK to accept the defaults on the Create Report dialog and open the Report dialog. 2. Select Device Properties as the Category in the Report dialog. Select one or more of the outputs in the Quantity listing, along with the corresponding Functions. Click Add Trace and Done to close the Report dialog and display the outputs. HFSS视频教程 ADS视频教程 CST视频教程 Ansoft Designer 中文教程 |