首页 >> CST教程 >> CST2013在线帮助系统 |
Monitor on Solids or VolumesSimulation: Monitors Monitor on Entity Monitor on VolumeThis dialog box gives you the opportunity to define monitors for transient simulations. You might need these monitors to obtain additional information on the electromagnetic field distribution inside your structure. After a calculation, you can observe your monitors by selecting them in the navigation tree.Name and type definition Name: Displays the name for the monitor either as a user input or automatically generated. Automatic labeling: This check button enables or disables the automatic labeling for the defined monitor. The automatically generated label consists of the selected monitor type, including the specified solid settings. Type: This drop-down list offers a variety of monitors. The currently available monitor types allow the observation of Energy, Co-energy, Coil Voltages, Force and Torque and Ohmic Losses. Monitor settings Everywhere/all domains: Evaluation of the specified function (monitor type) in the entire computation domain. Select subvolume: Enables a drop-down list from which a solid, a coil or a solid wire can be chosen.
Please note that Coil Voltages can be evaluated only on coils and Forces can be evaluated only on non-sheet and non-hybrid solids as well as on coils and solid wires. The options "background" or "all domains" are not available for these monitor types.
Extend to touching shapes: This check box is available only for the Forces and Torque monitor type. The force computation method requires objects which are surrounded completely by the background or by objects that are equivalent to the background. An object is considered as equivalent to the background if
When the checkbox is activated all shapes connected to the selected solid or coil will be collected into one group and the force on this group will be computed. Otherwise the force will be computed only on the specified object, but a warning will be printed if shapes are detected which are not entirely embedded in background or equivalent material. Please note that the background and equivalent objects are ignored by the force computation method, but the selected object will never be ignored. Please see Force and Torque Calculation for further information.
Torque normal / Torque origin: Available only for the Forces and Torque monitor type. In these 6 edit fields the position and orientation of the torque axis can be specified. OK Accepts your settings and leaves the dialog box. Cancel Closes this dialog box without performing any further action. Help Shows this help text. See also LF Time Domain Solver, Solver Overview, Modeler View HFSS视频教程 ADS视频教程 CST视频教程 Ansoft Designer 中文教程 |
Copyright © 2006 - 2013 微波EDA网, All Rights Reserved 业务联系:mweda@163.com |