CST MWS如何查看损耗在各个材料中的分配
05-08
计算了一个结构材料,由自定义的Lossy metal和Lorentz model的电介质2种材料构成,用时域算完以后用后处理计算了在2个吸收频率处的Thermal losses,结果如下(8个结果对应8个场监视器):
Computed 8 thermal loss distributions.
-----------------------------------------------------------------------------------
1: current (f=1.088)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic Current
Loss Type : Electric Volume Loss
Total Loss: 2.461336e-001 W (rms)
2: current (f=1.148)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic Current
Loss Type : Electric Volume Loss
Total Loss: 2.535106e-001 W (rms)
3: e-field (f=1.088)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic E-Field
Loss Type : Electric Volume Loss
Total Loss: 2.461336e-001 W (rms)
4: e-field (f=1.148)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic E-Field
Loss Type : Electric Volume Loss
Total Loss: 2.535107e-001 W (rms)
5: h-field (f=1.088)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic H-Field
Loss Type : Surface Loss
Total Loss: 2.269823e-001 W (rms)
6: h-field (f=1.148)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic H-Field
Loss Type : Surface Loss
Total Loss: 2.245989e-001 W (rms)
7: loss (f=1.088)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic Loss density
Loss Type : Electric Volume Loss
Total Loss: 1.877123e-001 W (rms)
8: loss (f=1.148)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic Loss density
Loss Type : Electric Volume Loss
Total Loss: 1.934078e-001 W (rms)
不知道怎么看损耗在金属和介质中的分配情况啊?难道Electric Volume Loss就是指介质的热耗散,Surface Loss就是指金属的焦耳热?(帮助里的两个公式实在不明白。)而且7、8计算的loss又是什么呢,如果是总消耗怎么数值比前面个都要小?求高手指点。
Computed 8 thermal loss distributions.
-----------------------------------------------------------------------------------
1: current (f=1.088)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic Current
Loss Type : Electric Volume Loss
Total Loss: 2.461336e-001 W (rms)
2: current (f=1.148)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic Current
Loss Type : Electric Volume Loss
Total Loss: 2.535106e-001 W (rms)
3: e-field (f=1.088)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic E-Field
Loss Type : Electric Volume Loss
Total Loss: 2.461336e-001 W (rms)
4: e-field (f=1.148)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic E-Field
Loss Type : Electric Volume Loss
Total Loss: 2.535107e-001 W (rms)
5: h-field (f=1.088)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic H-Field
Loss Type : Surface Loss
Total Loss: 2.269823e-001 W (rms)
6: h-field (f=1.148)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic H-Field
Loss Type : Surface Loss
Total Loss: 2.245989e-001 W (rms)
7: loss (f=1.088)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic Loss density
Loss Type : Electric Volume Loss
Total Loss: 1.877123e-001 W (rms)
8: loss (f=1.148)_1,1
Solver : Transient solver
Grid : Hex
Field Type: Dynamic Loss density
Loss Type : Electric Volume Loss
Total Loss: 1.934078e-001 W (rms)
不知道怎么看损耗在金属和介质中的分配情况啊?难道Electric Volume Loss就是指介质的热耗散,Surface Loss就是指金属的焦耳热?(帮助里的两个公式实在不明白。)而且7、8计算的loss又是什么呢,如果是总消耗怎么数值比前面个都要小?求高手指点。
相关文章:
- CST材料损耗角正切 (05-08)
- CST MWS仿真材料对电磁波的损耗 (05-08)
- CST MWS仿真介质的损耗 (05-08)
- CST MWS材料属性里损耗正切值怎么设置? (05-08)
- CST MWS中微波场能量损耗密度怎样仿真 (05-08)
- CST MWS如何求解波导损耗 (05-08)
射频专业培训教程推荐