这些ERROR怎么解?
虚心向高人学习,谢谢!
1. The port mode Eigensolver(本征求解器) failed because the maximum number
of iterations has been reached.
2. Single-ended definition requires a separate mode set for each pin
.Please check waveguide Port Number.
3. The propagation constant of mode1 is zero ,cannot continue.
4. Waveguide for port nuber 1 is too short. The waveguide must be
homogeneous for at least three mesh planes along propagation direction.
5. Too few conductors detected .Conductors might be short-circuited in
port plane.
6. On port 2 multiple potential definitions of the same set are located on one conductor ,or a symmetry condition is incompatible with the potential definitions.
4. Waveguide for port nuber 1 is too short. The waveguide must be
homogeneous for at least three mesh planes along propagation direction.
需要局部加密,选中靠近端口的组件,右键->local mesh properties->在XYZ方向上加密,直到你那个组件离端口最近的那部分加密到三个网格即可。
您遇到的问题主要都是波导端口的定义和端口处网格的定义上,答案如下。希望帮得上你。
1、这个提示并不是真正的本征模求解器的问题。CST的2008版以后的版本中对波导端口的求解精度进行了提高,每次进行仿真的时候,会自动对波导端口进行自适应网格收敛性分析,并得到精确的结果。这里出现这样的错误提示:主要是波导端口处的起始网格设置太粗,经过了4次(缺省值)网格迭代后仍不能达到指定的1%(缺省值)的精度要求,所以计算停止了。解决方法:提高端口处的起始网格或者取消自适应分析,更建议用前者。
2、要进行单端S参量计算,是要定义多芯端口的。CST丛书3中有多芯端口定义的详细介绍,老兄可以买来看看。也不贵!
3、真不知道您是怎样定义的波导端口,波导端口的传播常数为0啊,这当然不能继续进行下去了。
4、还是波导端口的问题,波导端口的定义要求端口面处,传播方向上至少要有3个网格才行的。
5、同样,断口处的网格太少,端口面上都短路了。
6、多芯端口定义的不对,这个错误说明您把多个电势定义到同一根内导体上了。这怎么行!建议你看看丛书3或者他们有本丛书9里面有个多层差分线的例子介绍的也挺好。
来自微波技术网的高手的回答,以后有问题也可以去那儿发。
http://imw.mwhrf.com/viewthread.php?tid=16910&pid=120978&page=1&extra=page%3D1
非常感谢..........
相关文章:
- CST5 : Error: Impossible to detect number of conductors in port no. 2 (05-08)
- The causes of these errors in CST MWS (05-08)
- 最近CST仿真老出错:Error in caculating solver matrix.Error in caculating solver matrix(parallelization enabl (05-08)
- CST2009报错:Render Engine Error 如何解决 (05-08)
- CST报错:Error in calculating solver matrix (parallelization enabled) (05-08)
- 用的是CST2011,出现的Error,该怎么办呢? (05-08)