帮助分析个warning 是怎么回事啊。
05-08
Warning detected by HPEESOFSIM during spectral noise analysis `HB_NOISE'.
The global circuit temperature and the IEEE standard noise temperature
(290 Kelvin) do not agree in the spectral noise analysis `HB2'. The
`Temp' parameter on the Options item can be set to 16.85 Celsius
to eliminate this warning message. If the circuit temperature is
different from the IEEE standard temperature the loss and the noise
figure might not agree.
就是在做噪声分析时,提示温度参数值与标准的290k不一致,请问如何修改参数解决该问题,保证仿真的噪声温度是正确的。
请各位大侠帮助哈!
The global circuit temperature and the IEEE standard noise temperature
(290 Kelvin) do not agree in the spectral noise analysis `HB2'. The
`Temp' parameter on the Options item can be set to 16.85 Celsius
to eliminate this warning message. If the circuit temperature is
different from the IEEE standard temperature the loss and the noise
figure might not agree.
就是在做噪声分析时,提示温度参数值与标准的290k不一致,请问如何修改参数解决该问题,保证仿真的噪声温度是正确的。
请各位大侠帮助哈!
The D#W{:_f
`Temp' parameter on the Options item can be set to 16.85 Celsius %jqBYn0q'
to eliminate this warning message.
您正在看的文章来自微波仿真论坛 原文地址:http://bbs.rfeda.cn/read-htm-tid-33755.html
温度是要符合IEEE标准的,而不是通常情况下的室温
添加一个OPTIONS控件,将仿真温度TEMP改为16。85就不会出现告警了
感谢大家的帮助.谢谢