Viewing the Phase Margin
For solutions in which convergence criteria for specific S-matrix entries were specified.
At any time during or after the solution process, you can view the solution’s proximity to the target delta phase, which was specified in the Matrix Convergence dialog box. The phase margin is available after two or more passes are completed.
To view the phase margin between passes:
In the project tree, right-click the solution setup of interest, and then click Convergence on the shortcut menu.
The Solution Data window appears. The Convergence tab is selected.
The Phase Margin column lists the phase margin from one pass to the next.
Note |
When the Mag S becomes small (near to zero) its phase becomes indefinite and insignificant due to mathematical issues so that Phase Margin will be discarded. |