HFSS online help > Viewing Analysis Results for Optimetrics Solutions
At any time during or after the Optimetrics solution process, you can see an overview of the computing resources or profile data that was used by HFSS as it solved each design variation. Optimetrics writes the variation information to the profile table before the solve. It then updates the entry with end data (end time, elapsed time, etc) once the solve variation is completed.
1. In the project tree, right-click the Optimetrics solution setup of interest, and then click View Analysis Result on the shortcut menu.
The Post Analysis Display dialog box appears.
2. Click the Profile tab.
3. Select the Optimetrics setup with the results you want to view from the pull-down list at the top of the dialog box.
4. Optionally, to examine more detailed profile data for a specific design variation, do the following:
a. Click a design variation in the table.
b. Click Solver Profile.
The Solutions dialog box appears with the profile data for the selected design variation.
The profile line for the matrix solver is in the following format:
Solver 123
where:
1 is the precision type: M (mixed) or D (double)
2 is the matrix data type: R (real) or C (complex)
3 is the symmetry type: S (symmetric), A (asymmetric), H (hermitian)