淘宝官方店     推荐课程     在线工具     联系方式     关于我们  
 
 

微波射频仿真设计   Ansoft Designer 中文培训教程   |   HFSS视频培训教程套装

 

Agilent ADS 视频培训教程   |   CST微波工作室视频教程   |   AWR Microwave Office

          首页 >> Ansoft Designer >> Ansoft Designer在线帮助文档


Ansoft Designer / Ansys Designer 在线帮助文档:


System Simulator >
System Component Models >
Probes >
   Histogram Probe (HISTP)       

Histogram Probe (HISTP)

 

 


Properties

Description

Units

Default

Range/Type

Name

Probe name

None

Required

String

nbin

Number of histogram bins

None

64

[1, Inf)/Integer

nsamp

Number of samples used for histogram

None

1024

[1, Inf)/Integer

Initsamp

Number of initial samples removed from waveform

None

0

[0, Inf)/Integer

RIN

Input impedance

Ohm

Inf

(0, Inf]/Real

Ports

Input

Input signal (real)


Notes

1. The maximum and minimum values for the input signal waveform are determined for histo­gram bin calculations. The histogram bins exist at intervals of dx = (Max_Input - Min_Input) / nbin. The bin centers are located at x[n] = (n + 0.5)*dx + Min_Input.

The total number of input samples per bin are determined and displayed versus the x-axis, rep­resented by the bin locations. If the user specifies a nsamp value larger than the total number received from the source, the actual number of samples received will be used for the histogram calculation.

Form

HISTP:NAME n1 nbin=val nsamp=val [Initsamp=val] [Rin=val]

Example

HISTP:1 1 nbin=64 nsamp=65536