Modifying a Variable Sweep Definition Manually

You can manually modify the variable values that will be solved for a parametric setup by explicitly changing, adding, or deleting existing points in a variable sweep definition under the Table tab of the Setup Sweep Analysis dialog box.

To manually modify a variable sweep definition:

1. Click the Table tab of the Setup Sweep Analysis dialog box.

The design variations HFSS will solve for the parametric setup are listed in table format.

You can edit table entries only when the sequence column (the first column) is sorted based on the defined sequence (the default). An asterisk (*) mark on the sequence column header denotes the default order, based on the sweep definition (whether ascending or descending), and not by increasing value. The numbering in the sequence column reflects the default.

Clicking on the sweep variable column headers sorts the table based on the value of that header. The sequence column numbers shift rows with the alternate display order, but the Add button is disabled when the table does not show the default order. The Add button is only enabled if the sequence column shows the asterisk that denotes the default order.

2. Do one of the following:

• To modify a variable value, click a value text box in the table and type a new value.

• To delete a variable value from the sweep definition, click the row you want to delete, and then click Delete. (You enable the Delete button by selecting a row.)

• To add a new variable value to the sweep definition, click Add.

This adds a new row at the end of the table. You can then click in the value text box and type a new value.

Your modifications are tracked and available for viewing at the bottom of the Setup Sweep Analysis dialog box under the Sweep Definitions tab. The operations you performed are listed with descriptions.

Warning

If you want to modify an original sweep definition using the Add/Edit Sweep dialog box after you have manually modified its table of design variations, your manual modifications will become invalid and will be removed.