Ansoft Designer / Ansys Designer 在线帮助文档:


Nexxim Simulator >
Nexxim Component Models >
Inductors >
   Ideal Inductor, Toroidal, N Taps       

Ideal Inductor, Toroidal, N Taps

 

[spacer]

Netlist Syntax

The general syntax for an ideal toroidal inductor with N taps is:

Axxxx n1 n2 ... nN N=val AL=val NT=[val val ...] COMPONENT=toroidal_inductor_n

n1 is the positive node, n2 through nN-1 are the taps, and nN is the negative node of the inductor. The current is assumed to flow from n1 through the inductor to nN.

The parameter COMPONENT=toroidal_inductor_n identifies the element as an ideal toroidal inductor with N taps.

 


Ideal Toroidal Inductor with N taps Instance Parameters

Instance Parameter

Description

Unit

Default

N

Number of taps

None

None

AL

Inductance per turn

1/Henry

None

NT

Number of turns for each coil section, space-separated list

None

None


 

Toroidal Inductor Instance Netlist Example

AtrindiT1 1 2 3 4 N=3 AL=5e-9 NT=[100 200 300]
+ COMPONENT=toroidal_inductor_n