The general syntax for an inductor instance is:

Lxxxx n1 n2 [[L=]val] [TC1=val] [TC2=val] [IC=val]

[SCALE=val] [M=val] [DTEMP=val] [TNOM=val] [R=val]

n1 is the positive node and n2 is the negative node of the inductor. The current is assumed to flow from n1 through the inductor to n2.

 


Inductor Instance Parameters

Instance Parameter

Description

Unit

Default

DTEMP

Inductor and circuit temperature difference

°C

0.0

L

Inductance

Henry

0.0

M

Multiplier to simulate multiple inductors in parallel

None

1.0

R

Series resistance

Ohm

0.0

SCALE

Scale factor for inductance

None

1.0

TC1

Linear temperature coefficient

°K-1

0.0

TC2

Quadratic temperature coefficient

°K-2

0.0

TNOM

Nominal temperature

°C

25.0

IC

Initial current through inductor

Ampere

None


Inductor Instance Netlist Examples

L1 1 2 L=5PH

L2 1 2 inductor1 L=5e-12 TC1=2

L3 1 2 inductor1 L=5e-12 SCALE=1.1

L4 1 2 L=1PF

Notes

1. The label L= is optional, but the presence or absence of the L= label affects the interpretation of other unlabeled entries in the statement. The first unlabeled value is taken to be the inductance value.

2. The syntax above shows the labels TC1= and TC2= as optional, but this option depends on the presence or absence of the inductance value, labeled or unlabeled.

3. When the inductance value is present but the inductance value does not have the L= label, the next two unlabeled values are taken to be TC1, then TC2. To specify a value for TC2, either a value for TC1 must be given as well, or the label TC2= must be used.

4. When the inductance value is present with the L= label, the labels TC1= and TC2= are required.

5. When the option device_cleanup=1 is in effect, a zero-valued inductor is replaced with a short circuit, and a warning is issued.