.OPTIONS and .TEMP statements can be supplied from external .INCLUDE and .LIB files (see External Files in the Netlist Format help topic).

A file imported with .INCLUDE is copied into the netlist at the point of the .INCLUDE statement. Thus, a setting made with .OPTIONS or .TEMP statements in a .INCLUDE file overrides settings made in earlier statements, and is overridden by later statements.

A portion of a file imported with .LIB is processed after all other statements in the netlist have been processed, and the order of processing of statements in .LIB files versus the main file cannot be determined in advance. Thus, if a .LIB block contains a .OPTIONS statement for a particular option, it should be the only setting for that option in the entire netlist. If a .LIB block contains a .TEMP statement, it should be the only .TEMP statement in the entire netlist.