淘宝官方店     推荐课程     在线工具     联系方式     关于我们  
 
 

CST视频教程推荐   CST微波工作室入门与应用详解   |  CST使用操作基础

          首页 >> CST教程 >> CST2013在线帮助系统

Simplify Model

Home: Mesh Global Properties [Simplify Model]
Simulation: SolverStart Simulation [Simplify Model]

Use  this dialog to globally reduce the complexity of your model.

Settings apply to

Solver: The simplification is used for the selected solver only.

Mesh:  The settings are used for the displayed mesh type only.

General

Simulate lossy dielectrics as lossfree: All lossy normal materials are treated as lossfree. In the Time Domain solver, the epsilon and mue infinity values of the dispersive material model are considered. The Frequency Domain, Integral Equation, and Eigenmode solvers take into account the dispersion of the real part of the complex permittivity and permeability only. This applies if the default settings are active. For a comparision with the Time Domain solver, please enable the Time Domain compatibility option for materials in the corresponding solver specials.

Simulate surf. impedance as PEC: All surface impedance materials (i.e. Lossy metal, Corrugated wall, Ohmic sheet and Tabulated surface impedance as well as coated materials) are treated as PEC.

Wires

Zero wire radius: The wire radius is globally set to zero for all  wires. (This setting is only available for hexahedral mesh.)

Apply  thin wire model to solid wires: Ignore all solid wire definitions.
Simulate lossy metal as PEC:
All lossy wires are treated as PEC.

OK

Press this button to apply the specified simplifications.

Cancel

Closes this dialog box without performing any further action.

Help

Shows this help text.

See also

Mesh Properties (Hexahedral), Mesh Properties (Tetrahedral)