首页 >> CST教程 >> CST2013在线帮助系统 |
Combine Calculation ResultsPost Processing: Combine ResultsIf you have made a calculation with two or more excitations (Waveguide Ports, Discrete Ports or Farfield Sources), you may combine the results using separate stimulation properties for each port. The new combined results will be shown in the navigation tree with a label in square brackets behind the monitor name.The combine operation can be executed either for all frequency monitors or for all time monitors (see also: Reference Value and Normalizing). Monitor settings frame Type: Choose here between a Frequency domain monitor or a Time domain monitor. Offset: The temporal delay between the stimulating time signals of the excitations may be specified by using either a time or phase shift. The phase shift offset requires a phase reference frequency: The phase values defined in the excitation list below are converted into corresponding time shifts for the time signals by use of this reference frequency. The offset setting applies only to time domain monitors. Monitor selection frame Selection...: Opens the monitor selection dialog. Frequency: If a frequency is selected, only the results available at this frequency will be combined. Monitor combination frame Label: Displays the label for the combined calculation results either as a user input or generated automatically. Automatic labeling: This check button enables or disables the automatic labeling for the combined result. The automatically generated label consists of the selected excitation combination including the specific amplitude and phase values. In addition, if time domain monitor is selected, the automatically generated label contains the reference frequency as well. You may define your own label name if you switch automatic labeling off. List: This list shows all previously defined labels belonging to combined calculation results, also including the labels created by a transient solver run with simultaneous port excitation activated. Excitation list Lists all excitations followed by the stimulation properties (amplitude and phase shift in degree resp. time delay) you have set. You can edit the amplitude and phase for each excitation here. Combine Performs your settings and creates a new result for each monitor. Leaves this dialog box. Close Closes this dialog box without performing any further action. Help Shows this help text. Set all... Opens the Excitation Properties dialog box where you can set the stimulation properties for all excitations. Clear Sets the stimulation properties for all ports to zero. See also Excitation Selection, Waveguide Ports, Monitors, Discrete Ports, Reference Value and Normalizing HFSS视频教程 ADS视频教程 CST视频教程 Ansoft Designer 中文教程 |
Copyright © 2006 - 2013 微波EDA网, All Rights Reserved 业务联系:mweda@163.com |