0D / Port ImpedancePost Processing: Result TemplatesTemplate Based Post ProcessingThis template allows to calculate/read out several port properties:
P/U: Z = U^2 / P U/I: Z = U / I MWS: Read out Line Impedance from MWS (Wave Impedance if Line Impedance is zero) For true TEM modes, all four results are identical. For inhomogeneous structures and so called Quasi TEM modes, the results differ. The voltage value U is integrated from the tangential electric field along an open curve, which has to be selected. The current value I is integrated from the magnetic field H along a closed curve, which has to be selected. The curves need to be defined before starting the macro. OK This button completes the setup of the template. The new entry will be added to the list of templates which are executed automatically after each run. The default name of the template is set according to the settings, as long the name has not been changed manually. Cancel Aborts the setup of the template and closes this dialog box without performing any further action. Help Shows this help text. See also Preloaded Result Templates, Calculate / Calculate analytical Line Impedance HFSS视频教程 ADS视频教程 CST视频教程 Ansoft Designer 中文教程 |