0D / HAC (Hearing Aid Compatibility of Mobile Phone)Post Processing: Result TemplatesTemplate Based Post ProcessingHAC evaluates the E- and H-nearfields of a radiating device, typically a mobile phone, in a 2D plane parallel to the front cover of the device, centered to the speaker point.
Pre-requisite to run the result template is therefore the definition of both E- and H-field monitores for the frequencies of interest. The speaker point needs to be marked with a working coordinate system (WCS) with the origin in the speaker point and the u-v-plane parallel to the front cover. The WCS needs to be stored (“WCS -> Store Current WCS…�
According to the specification of ANSI C63.19 a 50mm x 50mm area is spanned in 15 mm distance from the speaker point and subdivided in nine sub-grids. By unchecking the ANSI C63.19 checkbox user-defined areas can be considered. Also the resolution of the field evaluation can be specified (default: 1mm). Power Scaling: It can be chosen if the power is scaled to port power or to accepted (radiated) power. AWF: Depending on the transmission protocol an “Articulation Weighting Factor, AWF�gets defined. For CDMA, TDMA (50 Hz), UMTS (WCDMA) and TDMA (22Hz and 11 Hz) the AWF equals 0 dB, for GSM (217) it is -5dB. “Abs value = simple square sum� Instead of the real field vector maximum the absolute value gets computed from “Emax = Sqr(|Ex max|^2 + |Ey max|^2 + |Ez max|^2). This value is always larger then the real amplitude, but may represent the way typical measurement equipment is working. Logfile: The essential information of the HAC evaluation is shown in the logfile. All nine E- and H-fild values are shown in original and scaled form. Additionally the HAC category of each sub-grid value and those values that get excluded according ANSI C63.19. At the bottom the final HAC category is shown together with the global exclusion scheme: �T: Both E- and H are considered (“Taken� �E: E-Field got excluded �H: H-field got excluded �A: Both (“All� are excluded Show E / Show H: The E- or H-field in the plane of HAC evaluation is visualized. The plots get scaled to display both the minimum mand maximum value within the domain of evaluation (“scan area�. Additionally the nine sub-grids are displayed.
See also Preloaded Result Templates, Preloaded Macros Overview, Monitor HFSSÊÓƵ½Ì³Ì ADSÊÓƵ½Ì³Ì CSTÊÓƵ½Ì³Ì Ansoft Designer ÖÐÎÄ½Ì³Ì |
¡¡ |
Copyright © 2006 - 2013 ΢²¨EDAÍø, All Rights Reserved ÒµÎñÁªÏµ£ºmweda@163.com |