淘宝官方店     推荐课程     在线工具     联系方式     关于我们  
 
 

微波射频仿真设计   Ansoft Designer 中文培训教程   |   HFSS视频培训教程套装

 

Agilent ADS 视频培训教程   |   CST微波工作室视频教程   |   AWR Microwave Office

          首页 >> Ansoft Designer >> Ansoft Designer在线帮助文档


Ansoft Designer / Ansys Designer 在线帮助文档:


Nexxim Simulator >
Nexxim Component Models >
Nexxim Filters >
   Pole Zero Band Reject Filter       

Pole Zero Band Reject Filter

 

[spacer]

Netlist Syntax

An instance of a pole-zero band reject filter has the following Nexxim netlist syntax:

Axxx n1 n2 [FC=val] [BW=val] [GF=val] [R1=val] [X1=val] [R2=val] [X2=val] POLES=[rp1 ip1 ...] ZEROS=[rz1 iz1 ...] COMPONENT=polezero_bandreject_filter

n1 and n2 are the nodes connected to the filter. The entry COMPONENT=polezero_bandreject_filter is required.

 


Pole-Zero Band Reject Filter Instance Parameters

Parameter

Description

Units

Default

FC

Center frequency

Hz

0

BW

Bandwidth (3dB)

Hz

0

GF

Gain factor

None

1.0

R1

Resistive part of reference impedance at node 1

Ohm

50

X1

Reactive part of reference impedance at node 1

Ohm

0

R2

Resistive part of reference impedance at node 2

Ohm

50

X2

Reactive part of reference impedance at node 2

Ohm

0

rp1, ip1 ... rpN, ipN

Real and imaginary parts of the poles

None

None

rz1, iz1 ... rzN, izN

Real and imaginary parts of the zeros

None

None


Netlist Example

A22 1 2 FC=80e6 BW=101e4 POLES=[.1 -1.03 .2 .003]
+ ZEROS=[.05 -1.7] + COMPONENT=polezero_bandreject_filter

Notes

1. The element is specified using a transfer function given as the ratio of two expressions in the complex variable s. The bold brackets for the POLES and ZEROS entries are required.

The function of the device is expressed as:

GAIN ´ H(s)

The transfer function H(s) is specified by giving the coefficients:

[spacer]

 

 

[spacer]

where F = the analysis frequency and j=sqrt(-1)

 

 

[spacer]

 

 

[spacer]

 

 

 

[spacer]

 

 

2. The first coefficients in both numerator and denominator (a0 and b0) are constants, which must be specified even if they are zero. Thus, leading zeros are significant. In addition, intermediate zero-valued coefficients must be explicitly supplied in order to have the non-zero coefficients applied to the correct powers of s.

3. Trailing zeros are not significant, and are automatically removed.

4. At least one non-zero pole value must be supplied.




HFSS视频教学培训教程 ADS2011视频培训教程 CST微波工作室教程 Ansoft Designer 教程